SEMI OpenIR  > 中国科学院半导体研究所(2009年前)
Tolerance analysis for incident angle of volume phase holographic grating used in optical channel performance monitor
Xin HL; Li F; Cao P; He YJ; Chen P; Liu YL; Xin HL Chinese Acad Sci Inst Semicond Res & Dev Ctr Optoelect POB 912 Beijing 100083 Peoples R China.
2004
Conference Name3rd International Symposium on Instrumentation Science and Technology
Source PublicationPROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3
Pages31-35
Conference DateAUG 18-22, 2004
Conference PlaceXian, PEOPLES R CHINA
Publication Place16 FUXINGJIE NANGANGQU, HARBIN 150006, HEILONGJIANG, PEOPLES R CHINA
PublisherHARBIN INSTITUTE TECHNOLOGY PUBLISHERS
ISBN7-5603-2056-2
metadata_83chinese acad sci, inst semicond, res & dev ctr optoelect, beijing 100083, peoples r china
AbstractTransmission Volume Phase Holographic Grating (VPHG) is adopted as spectral element in the real-time Optical Channel Performance Monitor (OCPM), which is in dire need in the Dense Wavelength -division-multiplexing(DATDM) system. And the tolerance of incident angle, which can be fully determined by two angles: 6 and (p, is finally inferred in this paper. Commonly, the default setting is that the incident plane is perpendicular to the fringes when the incident angle is mentioned. Now the situation out of the vertical is discussed. By combining the theoretic analysis of VPHG with its use in OCPM and changing 6 and (0 precisely in the computation and experiment, the two physical quantities which can fully specify the performance of VPHG the diffraction efficiency and the resolution, are analyzed. The results show that the diffraction efficiency varies greatly with the change of 6 or (p. But from the view of the whole C-band, only the peak diffraction efficiency drifts to another wavelength. As for the resolution, it deteriorates more rapidly than diffraction efficiency with the change of (p, while more slowly with the change of theta. Only if \phi\less than or equal to+/-1degrees and alpha(B) -0.5 less than or equal to theta less than or equal to alpha(B) + 0.5, the performance of the VPHG would be good enough to be used in OCPM system.
KeywordOcpm Vphg Incident Angle Tolerance
Subject Area半导体器件
Funding OrganizationInt Comm Measurements & Instrumentat.; Natl Nat Sci Fdn China.; Chinese Soc Measurement.; China Instrument Soc.; Harbin Inst Technol.; Instrumentat Comm CSM.; Xian Jiaotong Univ.
Indexed ByCPCI-S
Language英语
Document Type会议论文
Identifierhttp://ir.semi.ac.cn/handle/172111/13585
Collection中国科学院半导体研究所(2009年前)
Corresponding AuthorXin HL Chinese Acad Sci Inst Semicond Res & Dev Ctr Optoelect POB 912 Beijing 100083 Peoples R China.
Recommended Citation
GB/T 7714
Xin HL,Li F,Cao P,et al. Tolerance analysis for incident angle of volume phase holographic grating used in optical channel performance monitor[C]. 16 FUXINGJIE NANGANGQU, HARBIN 150006, HEILONGJIANG, PEOPLES R CHINA:HARBIN INSTITUTE TECHNOLOGY PUBLISHERS,2004:31-35.
Files in This Item:
File Name/Size DocType Version Access License
2776.pdf(571KB) 限制开放--Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Xin HL]'s Articles
[Li F]'s Articles
[Cao P]'s Articles
Baidu academic
Similar articles in Baidu academic
[Xin HL]'s Articles
[Li F]'s Articles
[Cao P]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Xin HL]'s Articles
[Li F]'s Articles
[Cao P]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.