Knowledge Management System Of Institute of Semiconductors,CAS
Design of spectrometer based on volume phase grating for near infrared range | |
Li F; Xin HL; Cao P; Liu YL; Li F Res & Dev Ctr Optoelect POB 912 Beijing 100083 Peoples R China. | |
2004 | |
会议名称 | 3rd International Symposium on Instrumentation Science and Technology |
会议录名称 | PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3 |
页码 | 147-150 |
会议日期 | AUG 18-22, 2004 |
会议地点 | Xian, PEOPLES R CHINA |
出版地 | 16 FUXINGJIE NANGANGQU, HARBIN 150006, HEILONGJIANG, PEOPLES R CHINA |
出版者 | HARBIN INSTITUTE TECHNOLOGY PUBLISHERS |
ISBN | 7-5603-2056-2 |
部门归属 | chinese acad sci, inst semicond, state key lab integrated optoelect, beijing 100083, peoples r china |
摘要 | In order to design and fabricate a spectrometer for the infrared range widely used in the different applications, Volume Phase Grating (VPG) with. low Polarization Dependence Loss (PDL) and high efficiency has been adopted as the dispersion element. VPG is constructed by coating an optical substrate with a thin film of dichromated. gelatin and exposing the film to two mutually coherent laser beams to form index modulation. The diffraction efficiency for a VPG is governed by Bragg effects. The depth (d) and index modulation contrast of the grating structure control the efficiency at which the light is diffracted when the Bragg condition is satisfied. Gradient index lens with high performance and low aberration are used as collimating system instead of standard lens. The spot diagrams and MTF curve of the collimating lens are shown in the paper. The receive system is InCaAs photodiode (PD) array including 512 pixels with 25 mum pitch. The spectrum resolution of the spectrometer reaches to 0.2nm and wavelength accuracy is 40pm. |
关键词 | Spectrometer Volume Phase Grating Optical Design Resolution |
学科领域 | 微电子学 |
主办者 | Int Comm Measurements & Instrumentat.; Natl Nat Sci Fdn China.; Chinese Soc Measurement.; China Instrument Soc.; Harbin Inst Technol.; Instrumentat Comm CSM.; Xian Jiaotong Univ. |
收录类别 | CPCI-S |
语种 | 英语 |
文献类型 | 会议论文 |
条目标识符 | http://ir.semi.ac.cn/handle/172111/13559 |
专题 | 中国科学院半导体研究所(2009年前) |
通讯作者 | Li F Res & Dev Ctr Optoelect POB 912 Beijing 100083 Peoples R China. |
推荐引用方式 GB/T 7714 | Li F,Xin HL,Cao P,et al. Design of spectrometer based on volume phase grating for near infrared range[C]. 16 FUXINGJIE NANGANGQU, HARBIN 150006, HEILONGJIANG, PEOPLES R CHINA:HARBIN INSTITUTE TECHNOLOGY PUBLISHERS,2004:147-150. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
2763.pdf(371KB) | 限制开放 | -- | 请求全文 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Li F]的文章 |
[Xin HL]的文章 |
[Cao P]的文章 |
百度学术 |
百度学术中相似的文章 |
[Li F]的文章 |
[Xin HL]的文章 |
[Cao P]的文章 |
必应学术 |
必应学术中相似的文章 |
[Li F]的文章 |
[Xin HL]的文章 |
[Cao P]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论